The FR-A10005DS Fire Rated Monitored Double Mini Magnetic Lock is a compact maglock designed to secure both leaves of a double door. It can be used with compatible access control systems , emergency door systems and door entry systems .
The FR-A10005DS provides up to 600lbs (272kg) of holding force per door leaf and operates on selectable 12VDC or 24VDC . It features an aluminium housing and electroless nickel-plated armature plates. Its fail-safe design requires power to remain locked and releases when power is removed.
The lock status output indicates whether the magnets and armature plates are engaged, and the lock status LED provides a visual indication at the lock. A separate door status output provides door open or closed feedback to compatible equipment.
The lock has been fire tested to BS EN 1634-1 and is suitable for compatible FD30 and FD60 double fire doors , subject to the relevant fire test evidence and installation requirements.
Available Models
- FR-A10005DS – Fire-rated monitored double mini magnetic lock with a lock status LED and separate door status output.
Key Features
- Compact double mini maglock for paired door leaves
- Up to 600lbs (272kg) holding force per door leaf
- Selectable 12VDC or 24VDC operation
- Fail-safe operation (power to lock)
- Separate lock status and door status outputs
- LED lock status indication
- Aluminium housing and electroless nickel-plated armature plates
- Fire tested to BS EN 1634-1
- Suitable for compatible FD30 and FD60 double fire doors
Typical Applications
- Access-controlled double fire doors
- Internal double doors in commercial and public buildings
- Staff entrances and restricted areas
- Schools and educational facilities
- Healthcare premises
- Double doors requiring feedback on lock engagement and door position
Compatibility and Accessories
The FR-A10005DS can be used with compatible access control and door security equipment in new installations and retrofit projects. The connected equipment needs suitable inputs to receive the lock status and door status signals.
Before ordering, check the supply voltage, current draw, mounting arrangement and emergency release requirements. For fire doors, check that the door construction, fixings and accessories are covered by the relevant fire test evidence.
- Access control systems
- Emergency door systems
- Door entry systems and intercoms
- Keypad entry systems
- Proximity readers
- Emergency door release units
- Access control power supplies
- Compatible lock and door monitoring systems
- Compatible fire alarm interfaces
Technical Specification
- Model — FR-A10005DS
- Lock type — Fire-rated monitored double mini magnetic lock (maglock)
- Operating voltage — Selectable 12VDC or 24VDC
- Operation — Fail-safe (power to lock)
- Holding force — Up to 2 × 600lbs (272kg per door leaf)
- Lock monitoring — Monitored, with lock status output
- Door status output — Yes, for door open or closed feedback
- Lock status LED — Green when unlocked, red when locked
- Housing material — Aluminium
- Armature plate finish — Electroless nickel plated
- Fire testing — BS EN 1634-1
- Suitable door types — Compatible FD30 and FD60 double fire doors
- Dimensions — 42mm × 500mm × 26mm (H × W × D)
FR-A10005DS Product Information
The FR-A10005DS combines compact, fail-safe locking for paired fire door leaves with local LED indication and separate feedback on lock engagement and door position. It suits compatible double fire door installations that require up to 600lbs (272kg) of holding force per leaf .
Frequently Asked Questions
What is the difference between the FR-A10005 and FR-A10005DS?
Both models provide lock status monitoring and LED lock status indication . The FR-A10005DS adds a separate door status output for compatible systems that need door open or closed feedback.
What is the difference between lock status and door status monitoring?
Lock status monitoring indicates whether the magnets and armature plates are engaged. Door status monitoring indicates whether the door is open or closed. The FR-A10005DS provides these signals through separate outputs.
What does the lock status LED show?
The LED indicates lock status. It shows green when unlocked and red when locked .
What holding force does the FR-A10005DS provide?
The FR-A10005DS provides up to 600lbs (272kg) per door leaf , with two magnets in a single housing.
Is the FR-A10005DS suitable for fire doors?
Yes. It has been tested to BS EN 1634-1 and is suitable for compatible FD30 and FD60 double fire doors when fitted in an arrangement covered by the relevant fire test evidence.
Is the FR-A10005DS fail-safe?
Yes. The lock requires power to remain locked and releases when power to the lock is interrupted.
What voltage does the FR-A10005DS operate on?
The lock can be set to operate on 12VDC or 24VDC to match the installation’s power supply.
Can the FR-A10005DS be used with access control systems?
Yes. It can be used with compatible access control, door entry and emergency door systems. To receive both monitoring signals, the connected equipment needs suitable inputs for lock status and door status.