{"product_id":"fr-a10060-fire-rated-standard-double-magnetic-lock","title":"FR-A10060 Fire Rated Standard Double Magnetic Lock (Maglock)","description":"\u003cp data-pm-slice=\"1 3 []\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFR-A10060 Fire Rated Standard Double Magnetic Lock\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e or Maglock is an unmonitored electromagnetic locking solution designed for securing \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edouble doors\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in \u003c\/span\u003e\u003ca href=\"https:\/\/www.smartaccesssolutions.uk\/pages\/access-control\" title=\"Access Control Systems\"\u003e\u003cspan\u003eaccess control systems\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, \u003c\/span\u003e\u003ca href=\"https:\/\/www.smartaccesssolutions.uk\/collections\/eds-emergency-door-systems\" title=\"ICS EDS Enforcer Emergency Door System\"\u003e\u003cspan\u003eemergency door systems\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003ca href=\"https:\/\/www.smartaccesssolutions.uk\/pages\/intercom-systems\" title=\"Door Entry Systems\"\u003e\u003cspan\u003edoor entry systems\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e. Suitable for commercial, industrial, educational, healthcare, and public sector environments, it provides dependable locking for paired access-controlled doors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOperating from selectable \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e12VDC or 24VDC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the FR-A10060 delivers up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1200lbs (544kg) of holding force per door leaf\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2 × 1200lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e across the double-door installation. Manufactured with a durable aluminium housing and electroless nickel plated steel armature plates, it is designed for long-term reliability and consistent locking performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe FR-A10060 has been fire tested to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBS EN 1634-1\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is suitable for compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFD30 and FD60 double fire doors\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, subject to the relevant fire test evidence and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis model is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eunmonitored\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and does not include lock status monitoring or a door status output.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAvailable Models\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFR-A10060\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Fire-rated unmonitored standard double magnetic lock without door status output.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFire-rated standard double magnetic lock design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for double-door applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUp to 1200lbs (544kg) holding force per door leaf\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSelectable 12VDC or 24VDC operation\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFail-safe operation – power to lock\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAluminium lock housing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectroless nickel plated steel armature plates\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUnmonitored design\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFire tested to BS EN 1634-1\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for compatible FD30 and FD60 double fire doors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSuitable for access control and emergency door systems\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTypical Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCompatible FD30 and FD60 double fire doors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDouble access-controlled doors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommercial buildings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOffice entrances\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSchools and educational facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHealthcare premises\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePublic buildings\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRestricted access areas\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReception entrances\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInternal security doors\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCompatibility and Accessories\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFR-A10060 Fire Rated Standard Double Magnetic Lock\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed to integrate with compatible access control and door security equipment, making it suitable for both \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enew installations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eretrofit projects\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor fire-door installations, check that the door construction, fixing arrangement and accessories are covered by the relevant fire test evidence.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhen building a complete system, please check the lock voltage, current draw, door type, mounting requirements and any emergency release requirements before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smartaccesssolutions.uk\/pages\/access-control\" title=\"Access Control Systems\"\u003e\u003cspan\u003eAccess control systems\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smartaccesssolutions.uk\/collections\/eds-emergency-door-systems\" title=\"ICS EDS Enforcer Emergency Door System\"\u003e\u003cspan\u003eEmergency door systems\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smartaccesssolutions.uk\/pages\/intercom-systems\" title=\"Door Entry Systems\"\u003e\u003cspan\u003eDoor entry systems\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smartaccesssolutions.uk\/pages\/intercom-systems\" title=\"Intercom Systems\"\u003e\u003cspan\u003eIntercom systems\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smartaccesssolutions.uk\/collections\/proximity-reader-keypad-bluetooth\" title=\"Proximity Card Readers\"\u003e\u003cspan\u003eProximity card readers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smartaccesssolutions.uk\/collections\/keypad-proximity-bluetooth-reader-door-entry-access-security\" title=\"Keypad Entry Systems\"\u003e\u003cspan\u003eKeypad entry systems\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smartaccesssolutions.uk\/collections\/exit-buttons-infra-red-wireless-illuminated-touch\" title=\"Press to Exit Buttons\"\u003e\u003cspan\u003ePress to exit buttons\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smartaccesssolutions.uk\/collections\/emergency-break-glass-call-point\" title=\"Emergency Door Release Units\"\u003e\u003cspan\u003eEmergency door release units\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.smartaccesssolutions.uk\/pages\/additional-equipment\" title=\"Power Supplies Relays and Timers\"\u003e\u003cspan\u003ePower supplies, relays and timers\u003c\/span\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCompatible fire alarm interfaces\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Specification\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eModel:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e FR-A10060\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLock type:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Fire-rated standard double magnetic lock (maglock)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOperation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Fail-safe – power to lock\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOperating voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Selectable 12VDC or 24VDC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHolding force:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Up to 2 × 1200lbs (544kg per door leaf)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLock monitoring:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Unmonitored\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDoor status output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHousing material:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Aluminium\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eArmature plates:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Electroless nickel plated steel\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFire testing:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e BS EN 1634-1\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSuitable door types:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Compatible FD30 and FD60 double fire doors\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 67mm × 532mm × 40mm (H × W × D)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0018\/6698\/9679\/files\/FR-A10060.pdf?v=1781514784\" title=\"FR-A10060 Product Information\"\u003eFR-A10060 Product Information\u003c\/a\u003e\u003c\/p\u003e\n\u003cp dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFR-A10060 Fire Rated Standard Double Magnetic Lock\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides dependable electromagnetic locking for compatible double fire-door installations requiring up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1200lbs (544kg) holding force per leaf\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Featuring fail-safe operation, selectable \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e12VDC or 24VDC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e operation and fire testing to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBS EN 1634-1\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, it is suitable for applications requiring a durable standard double maglock without lock status or door status monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"auto\"\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 dir=\"auto\"\u003e\u003cstrong\u003eWhat is a double magnetic lock?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cspan\u003eA double magnetic lock, also known as a double maglock, is an electromagnetic locking device designed to secure both leaves of a double door. It provides electromagnetic locking across both doors from a single double lock housing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e\u003cstrong\u003eWhat does unmonitored mean?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cspan\u003eThe FR-A10060 does not provide an output confirming whether the magnets and armature plates are engaged. It also has no separate door status output.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e\u003cstrong\u003eWhat is the difference between the FR-A10060 and FR-A10060DS?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFR-A10060DS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e includes a separate \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edoor status output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing compatible systems to monitor whether the doors are open or closed. The FR-A10060 provides the same locking performance without this output. Both models are unmonitored in terms of lock engagement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e\u003cstrong\u003eHas the FR-A10060 been fire tested?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cspan\u003eYes. The FR-A10060 has been tested to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBS EN 1634-1\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is suitable for compatible \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFD30 and FD60 double fire doors\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, subject to the relevant fire test evidence and installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e\u003cstrong\u003eCan the FR-A10060 be used with access control systems?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cspan\u003eYes. The FR-A10060 can be used with compatible access control systems, card readers, keypads, intercom systems, door entry systems, press to exit buttons and emergency door release units.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e\u003cstrong\u003eWhat is the holding force of the FR-A10060?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cspan\u003eThe FR-A10060 provides up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1200lbs (544kg) of holding force per door leaf\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, giving \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2 × 1200lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e across the double-door installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e\u003cstrong\u003eIs the FR-A10060 fail-safe?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cspan\u003eYes. The FR-A10060 requires power to remain locked. When power to the lock is interrupted, it releases. Emergency release equipment and access controls must be correctly connected to interrupt the lock supply when required.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e\u003cstrong\u003eWhat operating voltage does the FR-A10060 require?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cspan\u003eThe FR-A10060 supports selectable \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e12VDC or 24VDC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"auto\"\u003e\u003cstrong\u003eIs the FR-A10060 suitable for retrofit installations?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp dir=\"auto\"\u003e\u003cspan\u003eYes, provided the existing door assembly, mounting arrangement and accessories are suitable for the lock and covered by the relevant fire test evidence.\u003c\/span\u003e\u003c\/p\u003e","brand":"ICS","offers":[{"title":"FR-A10060 Fire Rated Unmonitored double maglock","offer_id":57075170214263,"sku":"FR-A10060","price":106.95,"currency_code":"GBP","in_stock":true},{"title":"A500BP (armature fixing plate)","offer_id":57075170279799,"sku":"A500BP","price":9.3,"currency_code":"GBP","in_stock":true},{"title":"U520S (armature housing)","offer_id":57075170312567,"sku":"U520S","price":8.35,"currency_code":"GBP","in_stock":true},{"title":"A500ZL (Z\u0026L bracket kit)","offer_id":57075170345335,"sku":"A500ZL","price":14.85,"currency_code":"GBP","in_stock":true},{"title":"A500ZLDC (Z\u0026L bracket kit with cover)","offer_id":57075170378103,"sku":"A500ZLDC","price":28.45,"currency_code":"GBP","in_stock":true},{"title":"SDGi-L (Sliding adjustable L bracket 2 needed for double magnet)","offer_id":57400977523063,"sku":"SDGi-L","price":47.55,"currency_code":"GBP","in_stock":true},{"title":"LD-SM-SC Safety End Caps","offer_id":57075170443639,"sku":"LD-SM-SC","price":5.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0018\/6698\/9679\/files\/fr-a10060-fire-rated-standard-double-magnetic-lock.jpg?v=1783256426","url":"https:\/\/www.smartaccesssolutions.uk\/products\/fr-a10060-fire-rated-standard-double-magnetic-lock","provider":"Smart Access Solutions Ltd","version":"1.0","type":"link"}